Let’s talk about the ANSI/TIA-4966 data center standard first, many people may want to understand it. ANSI/TIA – 4966 In fact, it is a series of standardized standards for data centers. ANSI/TIA-4966 data center standards are very important in the industry. The purpose is to make the construction and development of data centers more standardized. For example, in all key links of the data center—

The first is the planning process. In terms of planning, it is necessary to determine the scale of the data center to achieve according to this standard. If you consider its future development, it is crucial to leave room for expansion.

1. Based on the business growth forecast, we need to calculate how much physical space is needed to place server storage devices.

2. The electricity and cooling requirements must be accurately evaluated. If the electricity and cooling cannot keep up, the equipment cannot operate stably, right?

Speaking of the power part, hey. Power distribution and power safety are strictly required in accordance with ANSI/TIA-4966.

1. The data center must build an uninterruptible power system to prevent sudden power outages from causing data loss or system crash.

2. Moreover, the redundant design of the power supply is essential to ensure that when some power supply equipment is broken, the other part can still hold on and not affect the overall situation.

Let's talk about cooling this. Oh yes, the cooling system is important in the data center.

1. Effective measures must be taken to distribute the heat generated by the equipment, such as the method of isolating hot and cold channels.

2. The air conditioning system must have sufficient capacity and ensure that the airflow distribution is well regulated to ensure that the equipment can be at the right temperature.

equipment layout. The layout must meet the ergonomic design, and the operation and maintenance requirements are also convenient for managers to fiddle with these equipment; and the communication wiring must be neat to avoid any signal interference. If this device is unreasonable, these factors will affect the work efficiency of the data center.

1. Key devices such as servers should be properly partitioned and set up each area to take into account the coordination between them.

2. High-quality cables should be used to connect the lines to meet the needs of high-performance data transmission.

Actually, there are still many details to pay attention to. Let's talk about some questions and answers.

Q: What would happen if the ANSI/TIA-4966 standard is not followed?

Answer: There will be many problems and do not follow them. If the power supply is unreasonable, the equipment is susceptible to power shock and easily damaged, and data may be lost. Is it cooled down badly? Excessive temperature may cause the equipment to lose performance after overclocking and directly shorten its life. It is difficult to find a device to troubleshoot the problem and make it difficult to solve the problem.

Then another question asked what they were here, and which data center types should follow this standard?

Answer: All types of bars generally have to follow basically; whether it is a commercial data center or

Data centers; even data centers that include cloud service providers; ANSI/TIA-4966 standards can provide reasonable guidance to ensure effective and orderly operation.

Then ask now and the difference from the previous data center standard section and talk about the difference. In the past, the standards focused on basic equipment layout and basic power guarantee situation. Now ANSI/TIA – 4966 can be considered more comprehensively; it involves energy-saving concepts, such as the development of power supply towards high-energy-efficient technologies, which are those good means of application; and there are also improvements in the integration of data centers and operation management. It now focuses more on overall performance while taking into account the operating experience of the staff

Let’s ask you what’s different from other similar international standards or what’s in contact with. Compared with other standards such as ISO standard, it mainly tends to guide international layout at the global level; AISO/SIA tends to serve specific regions or specialized industries, while ANSI/TIA – 4966 specifically introduces features that can better adapt to local and especially industry conditions. They are more or less similar to the overall goal, and they are seeking to develop based on providing a safe and reliable data environment, but there are differences in the starting point angle.

In fact, I think the ANSI/TIA-4966 standard is of great significance to protect the standardized construction of data centers from multiple angles. If a company wants to develop and expand, then the data operation will support it well and its foundation is stable and it is not afraid of changes.

Posted in