Speaking of this BS EN 50600 data center standard, this is very important in the data center industry and many people want to understand it. In the current environment of extremely digital development, data centers are also rising continuously. This BS EN 50600 standard is to properly restrict and guide data centers.

First, let’s talk about the general situation of this standard. BS, it represents the British Standard Society, and EN means European Standard. Therefore, BS EN 50600 not only complies with the British standard system, but also is linked to the European standard system, which has a dual guarantee! This standard covers many data center related content

1. Design module

1. Site aspect

When designing a data center, the site is crucial. It includes the size of the area, surrounding environment, geographical location, etc. For example, it is best to choose a data center site in a higher terrain and away from flood hazards and lower earthquake risks. It would be beautiful if there is no such large electromagnetic interference around.

2. Layout design

BS EN 50600 has strict control over the spatial layout of data centers. It requires that different functional areas must be clearly distinguished, such as equipment areas, office areas, monitoring rooms, etc., so that the division of labor can be clearly defined and comply with safety management. It is said that this can improve overall operating efficiency. Provide global procurement services for weak current intelligent products!

2. Construction module

1. Material application

What materials are used during construction are very important. This standard requires that the material must have flame retardant, environmentally friendly and other properties. Why? Of course, it is to avoid fire hazards and other things, so it makes the entire data center more in line with environmental protection requirements.

2. Installation operation

This standard also has various rules and regulations on the installation and operation of the equipment. All links must be operated rigorously, wires and cables must not be connected in a mess, and it is very important to properly install ventilation ducts in the air conditioning system.

III. Operation and maintenance management module

1. Daily inspection system

This inspection must be implemented! There must be very clear and detailed inspection plans and procedures. Check the operating status of each system, whether the screws are loose, and whether the temperature and humidity are suitable. It is stipulated that all equipment can maintain operation safely and reliably at all times

2. Emergency strategy planning

We must formulate emergency response strategies for unexpected situations such as power outages and fires! For example, setting up a reasonable backup power supply to ensure safe evacuation channels

Let's take a look at some FAQs

Q: What is the difference between BS EN 50600 and other data center standards?

Answer: It has the essence of both British and European standards! Unlike some countries' own separate standard BS EN 50600 data center standards, it is wider in scope and has a little higher international recognition! In addition, various requirements also comply with some of the key topics that have been mentioned in the current situation, such as sustainability and data security.

Q: Are there any changes in the cost to build a data center according to the BS EN 50600 standard?

Answer: From the perspective of the beginning, it will increase some initial investment costs, after all, the requirements for all aspects are higher. But in the long run, it will reduce the probability of various problems, thus saving a lot of operating costs.

Q: How to know whether the construction of data centers complies with the BS EN 50600 standard?

Answer: There are two major ways here. On the one hand, we check it step by step based on the standard documents. On the other hand, third parties can also be invited to conduct fair and independent evaluation structures for evaluation and review

I personally think that when so many data centers are developing vigorously, the BS EN 50600 standard is a powerful standard force. If you need to start the construction of data centers, you must do it seriously according to this standard!